Product Description
MKO-1 consists of:
The main controller GM-1JB/xS
The user terminal GM-1TB
Remote probe R-xM1 in cobines cover OSP-Kx.
In addition, MKO-12 version has intrinsically safe power supply type ZIB-1/x with cable to GM-1JB.
Methane detector in MKO-11 version is powered by an external intrinsically safe power supply 12V DC, and MKO-12 is powered from the alternating voltage source with a value determined by power supply ZIB-1/x. Main controller GM-1JB has a built-in battery which allows activation of methane detector before powering combine, measure the initial concentration of methane and then switching power supply control circuit of combine.
MKO-1X is a device of M1 category and may thus be used in all underground mines with possible methane or coal dust explosion hazard
Power supply: |
Un = 10V÷16V, In = 500mA (MKO-11 version)
24v or 42V or 230V AC, 40VA (MKO-12 version) |
Power supply autonomy: |
min. 8h when the battery is fully charged |
Measurement method: |
Continuous, infrared, gas penetration through diffusion |
Measurement range: |
0-100 CH4 |
Display: |
LCD |
Casing internal protection: |
IP55 |
Explosion-proof mark: |
I M2(M1)/M1 |
Type test certificate: |
TEST 15 ATEX 0042X |